Model 72x Series ***臭氧分析仪传输标准件(标准型及携带型)

Tanabyte 臭氧分析仪与传输标准件通过美国环保署认证,认证编号 (US EPA Equivalent Method EQOA-0407-165 ),产品可直接取代Dasibi 1008 系列臭氧分析仪,使用紫外光吸收法,符合环检所公告之空气中臭氧自动检验方法。
仪器具有自动温度压力修正功能,内建记忆体与SD卡储存,使用介面操作容易等特点,另外模组化设计使保养维修非常容易执行。
仪器外型可分成标准型及携带型,标准型独家双槽轨道化设计,可以于标准桌上型机壳内装入不同两种分析设备,未来扩充性强。
携带型重量约8公斤,适合目前室内空气品质监测使用,解决手持式灵敏度低之问题。
Model 722 Ozone Photometer Specifications
- Analog outputs: 4 isolated 16-bit outputs with ±100 mV to ±10V independently selectable ranges
- Full Scale Range: 100 to 10,000 PPB, independently programmable for each output
- Sample Flow Rate: .5 to 2.0 LPM, adjustable
- Photometer Cycle Time: 3 to 20 seconds, adjustable
- Zero Noise: < 0.0003 PPM
- Span Noise: < 0.5% of reading (above 100 PPB)
- Precision: < 0.5% of reading
- Linearity: < 1% of full scale
- Zero Drift: < .001 PPM per month
- Span Drift: ± 1% per month
- Lag / Rise / Fall Times: 10 / 20 / 20 seconds, respectively (with fast cycle setting)
Model 724 Ozone Transfer Standard
- Ozone Photometer 规格与 上面722相同
- Ozone Generator Specifications
- Ozone Output Range: 0 to 1000 PPB at 5 SLPM zero air flow, software selectable
- Minimum Non-zero Ozone: 1 PPB
- Ozone Output Resolution: 0.5 PPB
- Ozone Output Linearity: +/- 1% of range
- Zero Air Flow Rate: 2.5 to 6.5 LPM, software selectable
- Zero Air Pollutant Concentrations: NO, NO2, H2S, SO2, O3, Non-methane hydrocarbons < 1PPB
Gas Dilution Calibrator ***气体稀释校正器

Tanabyte is proud to present a comprehensive line of gas calibration instruments, designed with the specific needs of auditors, laboratory quality assurance engineers and site operators in mind.
Whether your need is for a precision gas dilution calibrator or an ultra-precise ozone standard, the pneumatics and electronics needed to perform the calibration function is mounted on a removable “module” that can be inserted into one of two types of enclosure or “Docking Stations”.
The Portable Docking Station is small and rugged - ideal for field auditors and traveling service personnel.
The Dual Docking Station supports two independent modules in a rack mountable enclosure. Its 5¼” height takes up less rack space than other rack-mount calibrators on the market, which are typically 7” or higher.
Model 322 Gas Dilution Calibrator
1. Dilution System Specifications
- Accuracy of Flow Measurements: +/- 0.5%
- Repeatability of Flow Control: +/- 0.1%
- Linearity of Flow Measurements: +/- 0.5%
- MFC Range for Dilution Air: 0 – 10 SLPM standard - other ranges available
- MFC Range for Dilution Gases: 0 – 100 SCPM standard - other ranges available
2. Ozone Generator Specifications:
- Ozone Output Range: 0 to 1000 PPB at 5 SLPM zero air flow, software selectable
- Minimum Non-zero Ozone: 1 PPB
- Ozone Output Resolution: 0.5 PPB
- Ozone Output Linearity: +/- 1% of range
- Nominal Ozone Flow: 100 SCCM
- UV Lamp Temperature: 50 +/- 0.1°C